EDAN - CHINA
Model : SE-1200E
Availability: Indent
Rp 35,600,000,-
  • Harga yang ditampilkan belum termasuk pajak dan ongkos kirim
  • Harga berubah setiap periode tertentu mengikuti perubahan kurs yang berlaku
  • Garansi 1 tahun

Garansi 1 tahun
Izin Edar
Kementrian Kesehatan RI Nomor : AKL-20502813773


12-channel ECG,8" Color Touch Screen

CMRR≥140 dB

Band width 0.05~150Hz

500 ECGs memory

Z-fold, Roll paper


Keunggulan

  •   8" high resolution color touch-screen
  •   Color-coded Signal Quality Indication
  •   800 ECG recordings storage capacity
  •   Extend printing once arrhythmia is detected
  •   Support linear/2D barcode scanner
  •   Support external printer via USB port
  •   Glasgow ECG Interpretation


Spesifikasi
Model
SE-1200E

Safety Specifications

Comply with

IEC 60601-1:1988+A1:1991+A2:1995
EN 60601-1:1990+A1:1993+A2:1995
IEC60601-1-2:2001+A1:2004
EN 60601-1-2:2001+A1:2006
IEC/EN60601-2-25
ANSI/AAMI EC11
IEC/EN 60601-2-51

Anti-electric-shock type

Class І with internal power supply

Anti-electric-shock degree

CF type with defibrillation-proof

Degree of protection against harmful

ingress of water

Ordinary equipment (Sealed equipment without liquid
proof)

Disinfection/sterilization method

Refer to the user manual for details

Degree of safety of application in the

presence of flammable gas

Equipment not suitable for use in the presence of
flammable gas

Working mode

Continuous operation

EMC

CISPR 11 Group 1, Class A

Patient Leakage Current

NC <10μA (AC) / <10μA (DC)

SFC <50μA (AC) / <50μA (DC)

Patient Auxiliary Current

NC <10μA (AC) / <10μA (DC)

SFC <50μA (AC) / <50μA (DC)

Environment Specifications

Temperature

Transport & Storage : -20ºC (-4ºF) ~ +55ºC (+131ºF)

Working : +5ºC (+41ºF) ~ +40ºC (+104ºF)

Relative Humidity

Transport & Storage : 25%~93% Non-Condensing

Working:  25%~80% Non-Condensing

Atmospheric Pressure

Transport & Storage : 700hPa ~1060hPa

Working : 860hPa ~1060hPa

Physical Specifications

Dimensions

420mm×330mm×105mm (16.5in×13.0in×4.1in)

Weight

Approx. 5.0kg (11.0 lbs)
(Excluding recorder paper and battery)

Display

320×240 dot single color LCD Screen
800×600 multicolor LCD Screen

Power Supply Specifications

Mains Supply

Operating voltage = 100V-240V~

Operating frequency = 50Hz / 60Hz

Input Current = 0.9-0.4A

Internal Li-ion Battery Pack

SE-1200 Express: Rated voltage = 14.8V
SE-1200: Rated voltage = 14.8V

SE-1200 Express: Rated capacity = 4400mAh
SE-1200: Rated capacity = 2200mAh

When the battery is fully charged, SE-1200 can work
normally about 4 hours, and it can continually print about
1.5 hours in the manual mode or print about 300 ECG
reports of 3×4+1R in the auto mode; SE-1200 Express can
work normally about 5 hours, and it can continually print
about 2.5 hours in the manual mode or print about 350 ECG
reports of 3×4+1R in the auto mode.

Fuse

T1AL250VP Ø5×20

Performance Specifications

Recorder

Thermal dot-matrix recorder

Printing Density

8 dots per mm / 200 dots per inch (amplitude axes)
40 dots per mm / 1000 dots per inch (time axes, @ 25 mm/s)

Recorder Paper

Folded thermal paper: 210mm×295mm×100pages
Folded thermal paper: 215mm×280mm×100pages
(Optional)
Rolled thermal paper: 210mm×30m (Optional)

Effective Width 203mm
Paper Speed 5mm/s, 6.25mm/s, 10mm/s, 12.5mm/s, 25mm/s, 50mm/s
(±3%)
Accuracy of data ±5% (x-axis), ±5%(y-axis)
HR Recognition Technique Peak-Peak Detection
HR Range 30 bpm ~ 300 bpm
HR Recognition Accuracy ±1 bpm
Leads Standard 12 leads
Acquisition Mode simultaneously 12 leads
A/D 24 bits
Time Constant ≥3.2s
Frequency Response 0.05Hz ~ 150Hz (-3dB)
Gain 2.5, 5, 10, 20, 10/5, AGC (mm/mV)
Input Impedance ≥50MΩ(10Hz)
Input Circuit Current ≤0.01μA
Input Voltage Range ≤±5 mVpp
Calibration Voltage 1mV±2%
DC Offset Voltage ±600mV
Noise ≤12.5μVp-p
Multi-channel Crosstalk ≤0.5mm
Filter

AC Filter: On / Off

DFT Filter: 0.05Hz / 0.15Hz / 0.25Hz / 0.32Hz / 0.5Hz /
0.67Hz

EMG Filter: 25Hz / 35Hz / 45Hz / OFF

LOWPASS Filter:150Hz / 100Hz / 75Hz

CMRR ≥115dB
Sampling Frequency 1000Hz
Pacemaker Detection
Amplitude ±2 to ±700 mV
Width 0.1ms ~ 2.0ms
Sampling Frequency 10,000/sec/channel
External Input/Output
Input ≥100kΩ; Sensitivity 10mm/V±5%;
Single ended
Output ≤100Ω; Sensitivity 1V/mV±5%;
Single ended

 

 

Tags: SE-1200E